Resources / Flex PCB heat dissipation
Design

Flex PCB heat dissipation for LED arrays.

  • Polyimide conducts heat at about 0.12 W/m·K, so a flex circuit moves heat through its copper, not its film.
  • A 190 cm² LED pad driven to 30-60 mW/cm² of light has to shed roughly 4 to 17 W of heat, depending on LED efficiency.
  • The fix is copper spreading, vias to a back plane and a metal stiffener or housing, all kept outside the zones that bend.

Flex PCB heat dissipation depends almost entirely on copper and on what the flex is bonded to. Polyimide film conducts about 0.12 W/m·K, thousands of times less than copper. So heat from LEDs and power parts is spread through copper pours, carried through vias to a backside plane, and passed into a metal stiffener or housing.

That last step is where flex differs from a rigid board. The flex is thin and light, so it has almost no mass to soak up heat.

Whatever it touches does the cooling.

Why do flex circuits run hot?

A flex circuit is a thin sheet of copper on a thin sheet of polyimide, often with acrylic or epoxy adhesive between them. The table shows how differently those layers carry heat.

MaterialThermal conductivitySource
Polyimide filmAbout 0.12 W/m·KDuPont Kapton HN data sheet
Aluminium 5052 stiffenerAbout 138 W/m·KAlloy 5052 material data sheet
CopperAbout 400 W/m·KHandbook value for pure copper

Copper carries heat more than 3,000 times better than the film it sits on. A small LED on a narrow trace has very little copper around it, so its heat stays at the pad and the junction runs hot. The board does not fail first. The LED dims, shifts colour and ages faster, and the adhesive under the copper softens.

How much heat does an LED array on flex produce?

Work it out from the light you need, not from the LED count. Light output per area times area gives optical power. Divide by LED efficiency to get electrical power, and the difference is heat.

LED pad, 100 x 190 mmLight outHeat to remove
30 mW/cm² over 190 cm²5.7 W3.8 W at 60% efficiency, 8.6 W at 40%
60 mW/cm² over 190 cm²11.4 W7.6 W at 60% efficiency, 17.1 W at 40%

The best 660 nm red LEDs now convert 78.8% of their electrical power into light, measured at a 25 °C junction (ams OSRAM, June 2023). Small packages, near-infrared parts and warm junctions do worse, so we budget mixed red and near-infrared arrays at 40% to 60% until the chosen parts’ data sheets are in. Two more points matter. Light measured at a treatment surface some distance away is less than the LEDs emit, so the heat figure grows. And efficiency falls as the junction warms, so a hot array makes more heat, not less.

Even the low case, a few watts across a thin sheet, needs a deliberate path out. The high case needs a heat sink.

How do you move heat out of a flex circuit?

Heat leaves a flex in three steps: sideways through copper, through the stack, then into something with mass. Each step has its own tool.

  • Spread it in copper. Tie each LED’s thermal pad to the largest copper pour the layout allows, not a thin trace. We build signal copper from 1/2 to 2 oz, and heavier copper up to 6 oz on busbar FPC designs. Heavier copper stiffens the flex, so keep it on the flat areas.
  • Pass it through the stack. On a double-sided flex circuit, an array of plated vias under each LED carries heat to a copper plane on the back face. Vias stay out of any region that bends.
  • Dump it into metal. An aluminium stiffener bonded behind the LED area is a heat spreader as well as a support. Bond it with a thin, thermally conductive adhesive; a thick standard tape undoes most of the gain. Where the housing is metal, bond the flex to it directly.
  • Spread the load. Even LED spacing avoids hot spots. The same power spread over the whole pad runs cooler than the same power packed into one corner.

We bond polyimide, FR-4, aluminium and stainless steel stiffeners, and the hole-to-edge rules for metal stiffeners are covered in our flex PCB manufacturing process guide.

Which flex materials suit hot LED arrays?

The film is rarely the limit. Polyimide tolerates far more heat than the LEDs on it. The adhesive between copper and film is the weak layer.

Acrylic adhesive systems are the cheapest and most common. DuPont’s acrylic-based Pyralux LF adhesive is listed with a glass transition around 40 °C (Insulectro product data), so it is already soft at temperatures a busy LED array reaches. For arrays that run warm, we specify adhesiveless laminate, with copper bonded straight to polyimide, which we build on DuPont Pyralux AP and Taiflex laminates. The trade-offs are set out in our FPC materials guide.

Where should the temperature sensor go?

Put the NTC thermistor where the heat is, not where there is room. That means inside the LED cluster, on the same copper pour as the LED thermal pads, so it reads the copper temperature rather than the air.

With independent channels, such as separate red and near-infrared groups, use one NTC per zone. The controller then derates the hottest zone on its own instead of dimming the whole array. Keep the NTC and its traces on a flat area, like every other component.

How do you cool a flex that also has to bend?

Everything that removes heat also stops a flex bending. Thick copper, via arrays and metal stiffeners all belong on flat islands. The bend zones between them carry thin traces only.

Wearables and light-therapy pads that curve around the body are built this way. LEDs, NTC and stiffener sit on islands, and narrow flex bridges take the movement. How to size those bridges and how many flex cycles to test them to are covered in our guide to flex PCB bend radius and flex life.

From our flex line: The question we ask first on an LED flex is not how many LEDs, but how many watts reach the light and where the rest goes. If the answer is “into the air”, the design is not finished.

What this guide does not cover

The heat figures above are estimates from optical targets and assumed efficiencies, not measurements on a built part. Real junction temperature depends on the LED parts, drive current, housing and airflow, and should be confirmed by thermal simulation or a test build.

How much heat does an LED array on a flex PCB produce?
Optical power divided by LED efficiency, minus the optical power. A 100 x 190 mm pad giving 30-60 mW/cm² of light sheds roughly 4 to 17 W of heat at 40% to 60% efficiency.
Can an aluminium stiffener act as a heat sink on a flex circuit?
Yes. Aluminium conducts about 138 W/m·K against 0.12 for polyimide. Bond it behind the hot area with a thin, thermally conductive adhesive and keep it out of bend zones.
What is the maximum temperature a flex PCB can withstand?
Polyimide film handles far more heat than the rest of the build. The working limit is set by the adhesive system, components and solder. Adhesiveless laminate raises it.
Can you use thermal vias in a flex circuit?
Yes, in a double-sided or multilayer flex, under the hot components and only in flat areas. Plated holes in a bend zone crack.
Where should an NTC thermistor go on an LED flex?
Inside the LED cluster, on the same copper as the LED thermal pads, with one per independently driven zone so each can be derated on its own.

Designing an LED flex that runs hot?

Send the outline, LED list and target light output. We check the heat path and stack-up and reply in two working days.