- A flexible PCB can be shielded three ways: a copper ground layer, printed silver ink, or a laminated shield film.
- Shield film is the thinnest of the three, which is why it is the usual choice on flex that has to bend.
- Every shield acts as a reference plane, so it belongs in the stack-up before controlled impedance is calculated.
A flexible PCB is shielded from EMI with a copper ground layer, a printed silver layer or a laminated shield film, each grounded to the circuit through openings in the coverlay. Film adds the least thickness and bends best. A copper layer shields well but stiffens the flex. Every option changes impedance and bend radius.
Shielding is often added late, after a prototype fails an emissions test or picks up noise from a nearby antenna or motor driver.
It can be added late. But the shield changes the stack, the bend and the impedance, so it costs less to plan it with the first layout.
What is EMI shielding on a flexible PCB?
EMI shielding is a conductive layer laid over the signal traces and tied to ground. It keeps radiated noise inside the flex and stops outside noise from coupling into it. A rigid board often gets a metal can for this job; a flex has no room for one, so the shield has to be part of the circuit.
It matters most on flex that runs between boards: camera and display interconnects, sensor leads, and any long tail that passes a radio or a switching power stage.
Which shielding methods work on flex?
| Method | Effect on thickness and bend | Best fit |
|---|---|---|
| Copper ground layer, solid or cross-hatched | Adds a full copper layer and its dielectric. The stiffest option; cross-hatching gives back some flexibility | Static flex, or where a defined reference plane matters more than bending |
| Printed silver ink | A thin conductive print over the coverlay, cured in place | Lower-cost static designs with modest shielding needs |
| Laminated shield film, silver or copper type | The thinnest option, laminated like a coverlay | Flex that bends in service, and thin tails that still need full coverage |
How thin is thin? One shield film maker lists products down to 8 µm total thickness, with grades made for dynamic bending. An earlier film from the same maker, reported in June 2005, was 22 µm: 5 µm of epoxy, 0.1 to 0.15 µm of silver and 17 µm of conductive adhesive. Either is far thinner than an extra copper layer with its own dielectric.
We laminate both conductive silver film and copper-type shield film, on one face of the flex or both. The choice comes down to how much the part bends, how thin it has to stay and how much attenuation the product needs. The base materials underneath are covered in our guide to flex circuit materials.
How is a shield film grounded to the circuit?
A shield only works if it is tied to ground at enough points. The usual route is a window opened in the coverlay over a ground trace or pad, so the film’s conductive adhesive bonds straight to the copper underneath. Where a window is not practical, silver paste or a conductive adhesive makes the connection instead. We build both.
The windows are small, so registration decides yield. Our standard capability is a smallest square coverlay window of 0.5 x 0.5 mm, a cumulative coverlay tolerance of ±0.10 mm on machine lamination, covering position, adhesive squeeze-out and size, and a minimum of 0.1 mm between coverlay and pad.
Spread the ground windows along the shield rather than bunching them at one end, so the whole film sits at ground and no section floats.
What does shielding do to bend radius and flex life?
Bend radius is set as a multiple of total thickness, so anything laminated on top of the flex raises the minimum radius. A dynamic flex already needs about 100 times its thickness under IPC-2223. A few microns of film move that limit much less than a copper layer does.
Two habits keep a shielded flex reliable when it moves. Stop any copper shield short of the dynamic zone and use film there. And keep the ground windows out of the bend, for the same reason our flex design rules keep vias out of the fold: an opening in the coverlay is a stress point.
How does a shield change impedance?
A shield is a conductor sitting close to the traces, so it becomes a reference plane whether it was planned as one or not. Laminate film over a 50 ohm line that was calculated without it, and the impedance drops.
The shield therefore goes into the stack-up model from the start, with its thickness, its adhesive and its distance to the traces. We hold controlled impedance to 50 ohm ±5 ohm single-ended and 100 ohm ±10% differential, with the shield in the calculation. Designs that need several routing layers plus a shield usually end up as a multilayer flex circuit.
From our flex line: Shielding is a lamination step we run alongside coverlay and stiffeners, with silver or copper-type film, on one face or both. The window, registration and impedance figures on this page are our standard capability, not a best case.
What this guide does not cover
It gives no shielding effectiveness in decibels. Attenuation depends on frequency, film type and the spacing of ground connections, and the honest number comes from testing your design.
It also does not compare film brands, and it does not cover shielding on rigid sections of a rigid-flex board, where a can or a ground pour is often the simpler answer.
Does EMI shielding film reduce flexibility?
Can you shield only part of a flex circuit?
Silver ink or shield film: which is better?
Do I need shielding on both sides of a flex?
How is the shield connected to ground?
Need a shielded flex?