Copper flex vs printed silver, decided by a 30 ohm limit.
- A keypad customer set a maximum circuit resistance of 30 ohms, and our first answer was to move the circuit from printed silver to copper flex.
- Before committing, the factory sampled a printed silver circuit on PET designed to stay under the limit. It passed.
- The customer approved the silver samples 68 days after the order. The cheaper construction won, and we think that was the right result.
Copper flex has roughly 15 to 30 times less sheet resistance than printed silver ink, so it is the safe answer to a tight resistance limit. But a 30 ohm limit sits inside the range printed silver can reach. In this job a silver circuit met it, and the customer approved the lower-cost build.
The order came in January 2019 with one electrical requirement that changed the conversation: circuit resistance no higher than 30 ohms.
That number decided which material the circuit layer could be.
What did the customer need?
The part was a keypad whose circuit layer, as ordered, was screen-printed silver ink on polyester film. That is the standard low-cost construction for simple switch panels. The drawing added a limit of 30 ohms on circuit resistance, which a printed silver trace does not meet automatically.
A long, narrow silver trace can easily exceed 30 ohms. So the first engineering question was whether to change the material or change the design.
Why did we first quote a copper flex circuit?
Because copper removes the question. The table compares sheet resistance, the resistance of one square of conductor of any size, for the two options.
| Conductor | Sheet resistance | Source |
|---|---|---|
| 1 oz copper, 35 um | About 0.5 milliohm per square | Calculated from copper resistivity, 1.72 micro-ohm cm |
| Silver ink, 25 um print | 8 to 15 milliohm per square | Supplier datasheets, Creative Materials membrane switch inks |
| Thinner silver prints | Higher, in proportion | Resistance rises as the print gets thinner |
At equal geometry, 1 oz copper is roughly 15 to 30 times more conductive than a 25 um silver print. A single-sided flex circuit would meet 30 ohms with a wide margin on any sensible layout, so we quoted one. The quote went out on 25 February 2019.
Why did printed silver pass anyway?
Resistance is sheet resistance multiplied by the number of squares in the trace, its length divided by its width. That means layout matters as much as material.
A worked example shows the scale. A silver trace 0.5 mm wide and 300 mm long is 600 squares. At 15 milliohm per square that is 9 ohms, well under the limit. The same trace would only reach 30 ohms at about 1,000 mm long, or if the print were much thinner.
Industry figures agree. One membrane switch maker gives printed silver circuits a range of less than 10 to 100 ohms on polyester. A 30 ohm ceiling sits inside that range, so a silver circuit laid out with care can meet it.
On 1 March the factory started sampling a printed silver circuit on PET built to meet the 30 ohm limit. Our record does not say which levers it used, wider traces, shorter routing, a heavier print or a different ink grade. It says the samples met the requirement.
How long did the decision take?
| Day | Date (2019) | Step |
|---|---|---|
| 0 | 17 January | Order released |
| – | Not recorded | Change to a copper flex circuit proposed to meet 30 ohms |
| 39 | 25 February | Copper flex circuit quoted as the safe option |
| 43 | 1 March | Printed silver samples started, designed to meet 30 ohms |
| 57 | 15 March | Samples shipped |
| 68 | 26 March | Customer approved the samples |
The detour through a copper quote cost some weeks. It also gave the customer both prices before the design was fixed, which is the useful part of an engineering review.
From our flex line: We make copper flex circuits, and we still tell customers when they do not need one. A resistance limit is a number to calculate against, not a reason to change material by default. Work out the squares first, then choose.
What this case does not show
Our record gives the limit, the dates and the result. It does not give the measured resistance of the approved samples, the trace dimensions or the ink grade, so the worked example above is illustrative, not this customer’s layout.
We also have no field data on the silver circuit after approval. The customer’s name and part number are left out.
When do you need copper flex instead of printed silver?
| If the circuit needs | Choose | Why |
|---|---|---|
| Resistance in the tens of ohms, switch contacts only | Printed silver on PET | Cheapest; meets the limit with a careful layout |
| A few ohms or less, or real current | Copper flex circuit | Sheet resistance 15 to 30 times lower |
| Soldered LEDs, resistors or connectors | Copper flex circuit | Silver ink cannot be reflow soldered |
For the soldered-parts case in practice, see our backlit keypad flex circuit case study. Base film and copper options are set out in FPC materials.
Is copper flex more conductive than printed silver ink?
Can a printed silver circuit meet a 30 ohm limit?
How do you calculate the resistance of a printed trace?
When is a copper flex circuit worth the extra cost?
Not sure your circuit needs copper?
Send the drawing and the electrical limit. We check the numbers and tell you which build meets it, in two working days.


