Resources / Copper flex vs printed silver case study
Case study

Copper flex vs printed silver, decided by a 30 ohm limit.

  • A keypad customer set a maximum circuit resistance of 30 ohms, and our first answer was to move the circuit from printed silver to copper flex.
  • Before committing, the factory sampled a printed silver circuit on PET designed to stay under the limit. It passed.
  • The customer approved the silver samples 68 days after the order. The cheaper construction won, and we think that was the right result.

Copper flex has roughly 15 to 30 times less sheet resistance than printed silver ink, so it is the safe answer to a tight resistance limit. But a 30 ohm limit sits inside the range printed silver can reach. In this job a silver circuit met it, and the customer approved the lower-cost build.

The order came in January 2019 with one electrical requirement that changed the conversation: circuit resistance no higher than 30 ohms.

That number decided which material the circuit layer could be.

What did the customer need?

The part was a keypad whose circuit layer, as ordered, was screen-printed silver ink on polyester film. That is the standard low-cost construction for simple switch panels. The drawing added a limit of 30 ohms on circuit resistance, which a printed silver trace does not meet automatically.

A long, narrow silver trace can easily exceed 30 ohms. So the first engineering question was whether to change the material or change the design.

Why did we first quote a copper flex circuit?

Because copper removes the question. The table compares sheet resistance, the resistance of one square of conductor of any size, for the two options.

ConductorSheet resistanceSource
1 oz copper, 35 umAbout 0.5 milliohm per squareCalculated from copper resistivity, 1.72 micro-ohm cm
Silver ink, 25 um print8 to 15 milliohm per squareSupplier datasheets, Creative Materials membrane switch inks
Thinner silver printsHigher, in proportionResistance rises as the print gets thinner

At equal geometry, 1 oz copper is roughly 15 to 30 times more conductive than a 25 um silver print. A single-sided flex circuit would meet 30 ohms with a wide margin on any sensible layout, so we quoted one. The quote went out on 25 February 2019.

Why did printed silver pass anyway?

Resistance is sheet resistance multiplied by the number of squares in the trace, its length divided by its width. That means layout matters as much as material.

A worked example shows the scale. A silver trace 0.5 mm wide and 300 mm long is 600 squares. At 15 milliohm per square that is 9 ohms, well under the limit. The same trace would only reach 30 ohms at about 1,000 mm long, or if the print were much thinner.

Industry figures agree. One membrane switch maker gives printed silver circuits a range of less than 10 to 100 ohms on polyester. A 30 ohm ceiling sits inside that range, so a silver circuit laid out with care can meet it.

On 1 March the factory started sampling a printed silver circuit on PET built to meet the 30 ohm limit. Our record does not say which levers it used, wider traces, shorter routing, a heavier print or a different ink grade. It says the samples met the requirement.

How long did the decision take?

DayDate (2019)Step
017 JanuaryOrder released
–Not recordedChange to a copper flex circuit proposed to meet 30 ohms
3925 FebruaryCopper flex circuit quoted as the safe option
431 MarchPrinted silver samples started, designed to meet 30 ohms
5715 MarchSamples shipped
6826 MarchCustomer approved the samples

The detour through a copper quote cost some weeks. It also gave the customer both prices before the design was fixed, which is the useful part of an engineering review.

From our flex line: We make copper flex circuits, and we still tell customers when they do not need one. A resistance limit is a number to calculate against, not a reason to change material by default. Work out the squares first, then choose.

What this case does not show

Our record gives the limit, the dates and the result. It does not give the measured resistance of the approved samples, the trace dimensions or the ink grade, so the worked example above is illustrative, not this customer’s layout.

We also have no field data on the silver circuit after approval. The customer’s name and part number are left out.

When do you need copper flex instead of printed silver?

If the circuit needsChooseWhy
Resistance in the tens of ohms, switch contacts onlyPrinted silver on PETCheapest; meets the limit with a careful layout
A few ohms or less, or real currentCopper flex circuitSheet resistance 15 to 30 times lower
Soldered LEDs, resistors or connectorsCopper flex circuitSilver ink cannot be reflow soldered

For the soldered-parts case in practice, see our backlit keypad flex circuit case study. Base film and copper options are set out in FPC materials.

Is copper flex more conductive than printed silver ink?
Yes. One ounce copper has a sheet resistance of about 0.5 milliohm per square, against 8 to 15 milliohm per square for a 25 um silver ink print, roughly 15 to 30 times lower.
Can a printed silver circuit meet a 30 ohm limit?
Often, yes. Resistance depends on trace length and width as well as the ink. In this case a printed silver circuit on PET met a 30 ohm limit and was approved.
How do you calculate the resistance of a printed trace?
Multiply the sheet resistance by the number of squares, which is trace length divided by trace width. Adjust for print thickness, since sheet resistance is usually quoted at 25 um.
When is a copper flex circuit worth the extra cost?
When the circuit needs a few ohms or less, carries real current, or has soldered parts such as LEDs or connectors. For switch contacts alone, printed silver is usually enough.

Not sure your circuit needs copper?

Send the drawing and the electrical limit. We check the numbers and tell you which build meets it, in two working days.