Dual-access FPCB, copper reached from both sides.
A single-layer polyimide flex with windows in the base and coverlay, so the copper is contacted top and bottom, no plated holes, no second layer.
Both-side access without the second layer.
A dual-access FPCB is a single-layer flex with openings in both the base polyimide and the coverlay. The one copper layer is exposed from the top and the bottom, so you can solder or make contact on either face without a second copper layer or plated through holes.
That keeps the circuit as thin and as low cost as a single-sided flex, while giving the both-side connection that a design would otherwise pay for with a double-sided build. It is the efficient answer when you only need to reach one layer from two directions.
When you need both-side access.
The test is simple: does a pad have to be touched from two directions, or does the circuit just need routing on two layers? Those are different problems with different answers.
Dual-access
A pad is welded, soldered or probed on one face and contacted by a connector, spring or charger terminal on the other. One copper layer is enough for the routing. This is the case a dual-access build is for.
Double-sided flex
You need conductors on both faces, crossing over each other, joined by plated holes. That is routing density, not access, so it takes a two-layer flex circuit.
Single-sided flex
Only one face is ever contacted. A coverlay opening on that side does the job at the lowest cost, so a one-layer flex circuit is the right build.
Busbar FPC
The connection carries pack-level current rather than signal. Heavy copper is the constraint, not access, which points to a busbar FPC for battery packs.
From our flex line: The request that reaches us most often is worded as a mask note, not a stack-up: the customer marks copper areas on the drawing and states they must be freely accessible from both sides. That sentence is a dual-access spec even when the drawing still says double-sided. Our pouch cell flex circuit case study walks through one such drawing, from mask note to quoted stack-up.
How the access is made.
The two-side access comes from windows, not from a second layer.

One copper layer
A single copper layer patterned on the polyimide base film.

Windows in the base
Openings are formed in the base film so the copper is reached from below.

Windows in the coverlay
Coverlay openings expose the same copper from the top face.

Gold both sides
Exposed pads are ENIG or gold plated for contact on either face.
The build envelope.
Typical ranges. Confirmed against your drawing and approved sample.
One copper layer, exposed from both sides.
Polyimide base with back-side access windows.
Rolled annealed for a flex that still bends.
Base and coverlay openings, registered front to back.
On exposed pads, both faces, for stable contact.
Single-layer flex bends freely between the access zones.
Under connector windows where a ZIF tail needs backing.
Built to IPC-6013, designed to IPC-2223.
The back window has to find the front pad.
On a dual-access flex, the back-side window must land exactly under the front-side pad, or the exposed copper shifts off the contact and the ZIF or solder joint sits half on film. So we register the back access to the front pattern, not to the panel edge, and check the alignment on the first article before the run.
Because there is no second layer to protect the copper, the exposed pads are plated on both faces and handled to avoid scratching the bared copper before assembly.
Thin interconnects, both-side contact.
A sample of the dual-access work we run. Every build starts from an approved sample and is accepted to IPC-A-610 Class 2 or 3.
Display tails
ZIF on one side, component or jumper contact on the other.
Sensor leads
Thin single-layer leads that terminate on opposite faces.
Camera flex
Compact interconnects between stacked camera boards.
Battery & power
Contact tabs reached from both sides of a thin flex.
Wearables
Low-profile interconnects where thickness is the constraint.
Consumer devices
Cost-sensitive both-side contacts without a double-sided build.
Common questions.
What is a dual-access FPCB?
How is dual-access different from double-sided flex?
When would I use a dual-access flex circuit?
What finish goes on the exposed pads?
Often supplied alongside.
Send your dual-access drawing.
Pad locations, which faces need access, finish and quantity. We reply with feasibility and an indicative price in two working days.