Power distribution

Busbar FPC, heavy copper for high current.

Flexible circuits built with heavy copper to distribute high current in battery packs, EV and power modules, replacing rigid busbars and wiring.

6 oz
Heavy copper, up to
100A+
High-current distribution
Sense
Power + signal on one flex
IPC-6013
Built and inspected to
What it is

A busbar that bends to fit.

A busbar FPC is a flexible circuit built with heavy copper so it distributes high current the way a rigid metal busbar would, but folds around cells and modules. It replaces bolted rigid busbars and hand-run wiring with one flexible part that drops into the pack.

Because it is a printed circuit, the power conductors and the sense lines share the same flex. Voltage and temperature sensing are routed alongside the heavy copper, so the busbar and the monitoring wiring become a single assembly instead of two. Where a pack terminal has to be welded on the inside and touched by a charger or tool on the outside, that contact is usually built as copper reached from both sides of one layer rather than as a second copper layer.

The build envelope.

Typical ranges. Current capacity is sized to your temperature-rise limit and layout.

Copper weight
2 to 6 oz

Heavy copper for high-current conductors.

Current
tens to 100s A

Set by copper weight and conductor width.

Base film
Polyimide

Flexible dielectric that folds around cells.

Integration
Power + sense

Heavy power traces and thin sense lines on one flex.

Terminations
Nickel tabs

Nickel or copper tabs for cell and module contact.

Connectors
Fitted

Signal connectors for the BMS assembled on the flex.

Finish
ENIG / Ni

For low contact resistance at the terminations.

Standard
IPC-6013

Built to IPC-6013, designed to IPC-2223.

From our flex line

Heavy copper needs room to shed heat.

The number that decides a busbar FPC is temperature rise, not just current. A conductor sized only for the amps runs hot and ages the polyimide, so we size copper weight and width to a target rise, and open coverlay over the heavy traces where the design allows the copper to radiate.

Etching thick copper undercuts the trace, so on heavy-copper flex we compensate the artwork for the etch factor, which keeps the finished conductor width on target and the current rating honest.

SizingTo a temperature-rise limit, not just amps
CoolingCoverlay opened over heavy traces where allowed
Etch factorArtwork compensated so width stays on target
Where busbar FPC ships

Power that has to fold.

A sample of the busbar FPC work we run. Every build starts from an approved sample and is accepted to IPC-A-610 Class 2 or 3.

Battery packs

Cell-to-cell interconnect with integrated voltage sensing.

EV & e-mobility

Module busbars that fold into tight, vibrating packs.

Energy storage

High-current distribution across stacked cells.

Power modules

Compact power routing where a rigid busbar will not fit.

LED lighting

High-current carriers that wrap a fixture.

Industrial power

Flexible distribution in drives and inverters.

Common questions.

What is a busbar FPC?
A busbar FPC is a flexible circuit built with heavy copper to carry high current, so it distributes power the way a rigid metal busbar would but bends to fit. It replaces rigid busbars and wiring harnesses in battery packs and power modules.
How much current can a busbar FPC carry?
Current capacity is set by copper weight and trace width. With heavy copper from 2 oz up to 6 oz and wide conductors, a busbar FPC carries tens to hundreds of amps, sized to your temperature rise limit.
Why use a busbar FPC instead of a rigid busbar or cables?
A busbar FPC folds around cells and modules, integrates sense lines and connectors, and removes the bolted joints and hand wiring of a rigid busbar. That saves weight and assembly time and cuts the joints that fail under vibration.
Can a busbar FPC include sense lines?
Yes. Heavy-copper power conductors and thin sense or signal traces can run on the same flex, so voltage and temperature sensing is integrated into the busbar rather than added as separate wiring.

Send your busbar FPC layout.

Current, cell layout, sense points, terminations and quantity. We reply with feasibility, a copper plan and an indicative price in two working days.